Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments

All Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments

H.V. TESTER from 2.5 to 200 KV
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
  Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments  Documentation
  Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Software
  Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments  Send Enquiry
INTRODUCTION

Every electrical apparatus or machine Is provided with insulation between live part and earth or between two different sections of live parts. This insulation is required to be tested at high voltage values recommended by applicable relevant standards.
The standard Specification for various electrical apparatus specifies Power Frequency Voltage withstand test at different levels depending upon working voltage of electrical apparatus. It is observed from the various standards for electrical equipments that the minimum power frequency voltage withstand test level for electrical insulation is 2kV for one minute.
We have, therefore, standardized on manufacture of'AE' High Voltage Breakdown Testers with rated voltage of 5kV.

High Voltage Tests Sets of higher voltage upto 600kV are also manufactured against specific requirement. The standard voltages are 10kV, 15kV, 20kV, 25kV, 30kV, 50kV,100kV, 150kV, 200kV & 300kV. The test sets uplo 30kV are manufactured in Air Cooled design while the sets of 50kV & above are manufactured in Oil Cooled design. The output of these high voltage testers is single phase 50/60Hz. The standard H.T. current rating of air-cooled design as also of oil cooled design upto 150kV is 100mA for 30 minutes. For voltages ranges above 'AE' make 5kV A.C. (with 2.5kV tap) High Voltage Breakdown Tester is portable, sturdy & plug in to start type construction & requires minium table space. It broadly consists of 3 main sections.

1) High Voltage Transformer
2) Variable Voltage Source
3) Control Circuit


1) HIGH VOLATGE TRANSFORMER :

The High voltage transformer is single phase, single pole type & is of double wound resin moulded
construction. The H.T. winding is provided with graded insulation such that one end is insulated for 2kVinsulation and is earthed through a current sensing transformer & miiliammeter whereas other end isinsulated for full rated voltage & the same brought out through H.T. Cable & spring loaded Prod.

2) VARIABLE VOLTAGE SOURCE :

Variable Voltage supply is provided through a Dimmerslat (Variable auto-transformer) havingasuitable rating corresponding to the rating of H.V. Transformer. Dimmerstat Is rated for 230Volts A.C. input & 0-270V output. Limit switch at zero position end of Dimmerstat winding is provided to facilitate the H.T. winding to

3) CONTROL CIRCUIT & OTHER FEATURES :

ManuaIly operated control transformer (VariabIe auto-transformer) with zero interlock facility.

72mm sq. double range (0-2kV / 0-5kV) moving coil rectifier type voltmeter of class 1.5, provided to read NO LOAD H.T. Voltage.

72mm sq. double range (0-100mA) moving coil rectifier type A.C. Milliammeter of class 1.5, provided in the earth end of the H.T. winding to read H.T. Current.

Automatic tripping circuit is provided for isolation of supply, in the event of failure of the object under test. Rotary switch with four different settings of 5,10, 50 & 100mA is provided on front panel with LED indication

M.C.B. for short circuit protection of H.T. transformer & auto transforme

H.T. ON push button, Mains ON & H.T ON LED indication.

Range selection switch to select 2.5kV or 5kV range with LED indication.

Two spring loaded test prods with 1 metre long cable for safe & easy connection of high voltage to test object, (upto 5kV.)


DIMENSIONAL DRAWING :
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
CIRCUIT DIAGRAM :
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments 1. MINITATURE CIRCUIT BREAKER
2. DIMNERSTAT
3. AUXILIARY TRANSFORMER
4. VOLTAGE RANGE INDICATOR
5. KILO VOLT METER
6. RANGE SELECTOR SWITCH
7. MAIN 'ON' LED YELLOW
8. H.T. ON LED RED
9. H.T. ON PUSH BUTTON
10. MAIN RELAY COIL
11. MAIN RELAY
12. HIGH VOLTAGE TRANSFORMER
13. MILLIAMMETER
14. TIMER CONNECTION LINK
15. TRIPPING ADJUSTMENT POT
16. TRIPPING C, Tr.
17. TRIPPING SELECTOR SWITCH
18. TRIPPING INDICATOR
19. EARTH TEST PROD BLACK
20. H.T.TEST PROD RED
21. D'STAT ZERO MICRO SWITCH
22. RECTIFIER
23. TRIPPING RELAY
24. BLEEDER RESISITANCE
DIMENSIONAL DRAWING :
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
Copyright 2010-2011 Automatic IT Services Pvt. Ltd. All Rights Reserved.