Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments

All Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments

REGULAR SHUNTS
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
  Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments  Documentation
  Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Software
  Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments  Send Enquiry

DESCRIPTION

The shunts are designed to comply with the requirements of IS1248 / DIN43703 & DIN43780. The shunt provides an accurate d.c. millivolt signal, exactly proportional to the system current


FEATURES
Rating 1A to 15000A
Riveted and soldered construction
In-line bus bar mounting
Very low temperature coefficient
High overload withstand
Shock and vibration Proof
Long term stability

TYPE
1) Insulated mounting

2) "I" Section

3) "L" Section


4) "T" Section
Ranges
1, 1.5,2,2.5, 3,4,5,6, 10, 15,20,25, 30 Amp.

30, 40, 50, 60, 75, 80, 100, 120, 150Amp.

200, 250, 300, 400, 500, 600, 750, 800, 1000,
1200, 1500, 2000, 2500, 3000Amp.

4000, 5000, 6000, 7500, 8000, 10000, 12000, 15000Amp.
ACCURACY 0.5%
CONTINUOUS
OVER LOAD
20% rated current
5 SECONDS WITHSTAND 10 times for 1 A to 500 Amp.
5 times for 600A to 2000Amp.
2 times for 2500A to 15000Amp.
TEMP. COEFFICIENT 0.002% per C.
AMBIENT TEMP. Calibration at 23C.
OPERATING TEMP. -10C to 55C.
STORAGE TEMP. -20C to 70C
MAXIMUM LOAD The load should not exceed 0.1% of the nominal current rating
for specified accuracy.
MILLIVOLT 50mV, 60mV, 75mV, l00mV, 150mV, 300mV (standard)
Other mV outputs on request.

NOTE :

Two cables of 1 meter length with 1.5mm cross sectional area are provided. This corresponds to a total resistance of 0.026 ohms. The instruments are calibrated with this resistance and consequently the cable length must not be changed. If different length or resistances are required, please indicate while ordering.


INSTALLATION
The best performance is guaranteed if the following points are observed.
1) Shunts may be mounted horizontally or vertically. Horizontal mounting gives the best heat dissipation.
2) Utilize the full end block surface area.
3) Ample ventilation should be provided.
4) Busbar should be adequately rated, cleaned & coated with a thin layer of silicon grease applied to the contact surface area.
5) Bolts and nuts must be carefully tightened.

CAUTION
Shunts are not insulated & protection against accidental contact may be necessary in order to comply with Health & Safety regulations.

Ordering information
1) Current rating 2) Millivolt output 3) Length of the cable

Rated Current
Amps.
Dim 'A' Max. Dim
'B1'
Dim
'B2'
Dim
'B3'
Dim
'C1'
Dim 'E' Dim 'H'
(mV) (mV) (mV)
60 75 100 150 300 60 75 100 150 300 60/75 100~300
1~30 90 90 90 90 90 20 - - 8 80 80 80 80 80 8 8
40~150 100 120 145 225 285 *20 - - 8 80 100 125 205 365 8 8
200~300 145 165 190 270 430 30 15 - 10 105 125 150 230 390 30 30
400~750 145 165 190 270 430 40 20 - 10 105 125 150 230 390 30 30
800~1000 165 185 210 290 450 *60 30 - 10 115 135 160 240 400 30 30
1200~1500 165 185 210 290 450 90 21 48 10 115 135 160 240 400 30 30
1600~3000 165 185 210 290 450 120 30 60 10 115 135 160 240 400 30 60
4000~5000 165 185 220 300 460 120 30 60 15 115 135 170 250 410 60 130
6000~7500 175 195 220 300 460 154 25 52 25 125 145 170 250 410 130 130
8000~10000 185 205 - - - 206 25 52 30 135 155 180 260 420 170 -
12000~15000 185 205 - - - 310 25 52 30 135 155 180 260 420 170 -

Rated Current
Amps.
Current
Terminal
Dim.
No. of
Current
Terminal
No. of
Current
Terminal
1~30 M 5x12 2 x 1 -
40~150 M 8x12 2 x 1 15
200~300 M 12x40 2 x 1 20
400~750 M 16x45 2 x 1 25
800~1000 M 20x50 2 x 1 40
1200~1500 M 16x45 2 x 2 40
1600~3000 M 20x50 2 x 2 40
4000~5000 M 20x50 2 x 2 40
6000~7500 M 20x75 2 x 3 40
8000~10000 M 20x85 2 x 4 40
12000~15000 M 20x85 2 x 6 40


Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
UPTo 30 Amps. 40 A To 150 A 200 A To 1000 A
 
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
1200 TO 3000 A 4000 A To 5000A
6000 A to 7500 A shunts
have 3 Boltsat each terminal spaced at lateral distance B3
8000 A To 10000 A
12000 A to 15000 A shunts have 6 Bolts
at each terminal spaced at lateral distance B3
 
Panel Meter,Transformer,Voltage Regulator/ stabilizer,Rectifier,Transducer,Break down tester,Test Bench,Relay test kit,Energy saver,Test measuring instruments
  8000 A To 10000 A
12000 A to 15000 A shunts have 6 Bolts
at each terminal spaced at lateral distance B3
 
(All Dimension are in mm)

Note :
1) Dimension A, E, H are the same for 50mV shunt & 60mV shunt.
2) Unless specified tolerance for mounting dimensions (Dim "E") shall be of 1.5mm upto 1500A rating & 2.0mm for the rating above 1500A.
3) Maximum value of 'H' is specified, Minimum value is equal to corresponding value of 'C1'.
4) *Dimension 20 & 60mm is for 60/75mV and 25 & 70 mm respectively for 100~300mV.
5) The consumption of measuring instusments should not exceed 500 microwatts for interchangeable     shunts.